Size | DN-15 (1/2″) to DN-6000 (200″) | ||||
Liquid type | Virtually all Liquids | ||||
Accuracy Class | ±1% of flow reading | ||||
Repeatability | 0.2% | ||||
Housing Material | ABS | ||||
Display | 4 X 16 Blacklit LCD display | ||||
Communication | Standard RS-232 | ||||
Totalizers | 7-digit totals for net, positive and negative flow respectively | ||||
Security | Setup values modification Lockout. Access code needed for unlocking | ||||
Transducers | S2H( Small Size) – DN15 to DN100 | ||||
M2H ( Medium Size) – DN 50 to DN 700 | |||||
L2 ( Large Size) – DN 300 to DN 6000 | |||||
Transducer Cord Length | 2 x 5m Standard, 10m Optional | ||||
Flow Rate Units | Meter, Feet, Cubic Meter, Cubic Feet, Liter, User Configurable | ||||
Data Logger | Built in datalogger can provide over 2000lines of data & Inbuilt Memory Card of 2 GB( Selected Models) | ||||
Response Time | 0-999 seconds , user-configurable | ||||
Protection Class | IP 65, IP67 ( Optional) | ||||
Velocity Range | upto 32 m/s | ||||
Power Supply | AAA Ni-H built in batteries with over 10hrs of charge for operation. 100V-240V AC charger provided |
Size | DN-15 (1/2″) to DN-6000 (200″) | ||||||||
Liquid type | Virtually all Liquids | ||||||||
Accuracy Class | ±1 % of reading at rates >0.2 mps | ||||||||
Repeatability | 0.2% | ||||||||
Linearity | ± 0.5% | ||||||||
Housing Material | ABS | ||||||||
Display | 4 x 16 English letters; 16 Key with tactile action | ||||||||
Totalizers | 7-digit totals for net, positive and negative flow respectively | ||||||||
Outputs | 1 way 4-20rnA output, 1 way OCT pulse output, 1 way relay output | ||||||||
Inputs | 3 way 4-20rnA input achieve to neat measurement by connecting PT100 platinum resistor | ||||||||
Transducers | S2H( Small Size) – DN15 to DN100, M2H ( Medium Size) – DN 50 to DN 700, L2 ( Large Size) – DN 300 to DN 6000 | ||||||||
Power Supply | 220VAC / 24VDC | ||||||||
Power Consumption | Less than 1.5W | ||||||||
Communication | RS485 |